MPM-GW-CI0-5045

Tac

2 offers available: $62.88–$634.23
maxohvac logo

MPM-GW-CI0-5045 Comparison

MPM-GW-CI0-5045 in Used Condition
photo price summary rating
Schneider Electric MPM-GW-CI0-5045 Wireless Manager w/315Mhz EnOcean & ZigBee Details$62.88Condition is Used, Schneider Electric MPM-GW-CI0-5045 Wireless Manager w/315Mhz EnOcean & ZigBee, shipping cost = $3.75100.0%
SCHNEIDER ELECTRIC MPM-GW-CI0-5045 / MPMGWCI05045 (USED) Details$634.23Condition is Used, SCHNEIDER ELECTRIC MPM-GW-CI0-5045 / MPMGWCI05045 (USED), shipping cost = $12.9099.7%
MPM-GW-CI0-5045 Schneider Electric

The Schneider Electric MPM-GW-CI0-5045 is a versatile and reliable power distribution unit (PDU) designed for use in IT environments. This PDU is part of Schneider Electric's MasterPact MT range, which is known for its high power density, compact design, and advanced features.

The MPM-GW-CI0-5045 is a 19-inch rack-mounted PDU, which makes it an excellent fit for standard IT racks. It can accommodate up to 50 outlets, with each outlet providing individual current monitoring capabilities. This feature allows IT administrators to monitor power usage at the outlet level, helping to optimize energy efficiency and prevent overloading.

This Schneider Electric PDU comes with a number of advanced features, including remote management capabilities. It supports SNMP, Telnet, and HTTP/HTTPS protocols, enabling administrators to monitor and manage the PDU from a remote location. Additionally, it includes an LCD display and user-friendly interface, allowing for easy local management.

The MPM-GW-CI0-5045 also includes built-in surge protection and short-circuit protection, providing an added layer of protection against power surges and short circuits. It is also equipped with an automatic shutdown function, which can be configured to turn off connected equipment in the event of an overload or power failure.

The PDU is designed to be energy efficient, with a high power factor of 0.95 and an efficiency of up to 96%. It also includes a power factor correction function, which helps to optimize power usage and reduce energy costs.

The MPM-GW-CI0-5045 is a robust and durable PDU, with a rugged aluminum housing and a fan-assisted cooling system. It is designed to operate in temperatures ranging from 0 C to 45 C, making it suitable for a wide range of IT environments.

Overall, the Schneider Electric MPM-GW-CI0-5045 is a powerful and feature-rich PDU that is ideal for IT environments requiring individual outlet power monitoring, remote management capabilities, and advanced power protection features. Its high power density, compact design, and energy efficiency make it an excellent choice for data centers, server rooms, and other IT applications.

Schneider Electric MPM-GW-CI0-5045: A Comprehensive Analysis of Its Pros and Cons

The Schneider Electric MPM-GW-CI0-5045 is a Powerlogic Power Monitoring Gateway that allows users to collect and analyze power data from various power sources. In this analysis, we will discuss the key features, advantages, and disadvantages of this device.

Features:

- Supports up to 253 I/O points

- Communication protocols: Modbus, IEC 61850, DNP3, and BACnet

- Built-in web server and SNMP agent

- Compact design

Advantages:

1. Wide Range of Communication Protocols: The MPM-GW-CI0-5045 supports multiple communication protocols, making it versatile and adaptable to various applications.

2. Scalability: With the capacity to support up to 253 I/O points, this device can cater to larger installations.

3. Remote Monitoring and Control: The built-in web server and SNMP agent enable users to monitor and control the device from a remote location.

Disadvantages:

1. Complex Configuration: The device may require a certain level of technical expertise to configure and optimize its settings.

2. Limited Display: The device itself does not have a large display, and data must be viewed through a web interface or other software.

Conclusion:

The Schneider Electric MPM-GW-CI0-5045 Power Monitoring Gateway offers a comprehensive solution for collecting and analyzing power data. Its wide range of communication protocols, scalability, and remote monitoring and control capabilities make it an attractive option for various applications. However, its complex configuration and limited display may pose challenges for some users.

Recommendation:

If you are looking for a powerful and versatile power monitoring solution, the Schneider Electric MPM-GW-CI0-5045 is an excellent choice. Its advanced features and capabilities outweigh the potential challenges associated with its complex configuration. To make the most of this device, consider investing in professional installation and configuration services to ensure optimal performance.

Details:

Sells new and surplus product develops channels to purchase such. Packaging and handling: items are safely eds packaged in custom shipping cartons for protection. All products are guaranteed to be working but may show signs of use if purchasing a used product. Schneider electric MPM-GW-CI0-5045 / mpmgwci05045 used discontinued by manufacturer, wireless gateway manager, series en ocean, for use w/ building/hvac automation, clip-on mounting, 315mhz frequency, gibe pro, 1.2w, 24vdc, 50/60hz, 3va.

Call to use a shipping service other than the ones listed.

specifications maxohvac:

returns maxohvac:

general maxohvac:

payments maxohvac:

shipping maxohvac:

offer maxohvac:

seller maxohvac:

rating: 99.5% out of 100 based on 663 user ratings.
Also Viewed: